MASSPHOTON Upper Room UV Air Disinfection / Upper-room UVGI System MP-UVC-15WR

MASSPHOTON UVC Upper Air Disinfection is an intelligent, sensor-based building-grade Upper Room UV Air Disinfection system powered by advanced UVC LED technology. It enables continuous Upper-room GUV operation in occupied spaces, drawing exhaled aerosols into the upper UV-C zone via natural or mechanical airflow for rapid pathogen inactivation—eliminating up to 99.99% of airborne threats more efficiently than HVAC-only systems.
 

Applicable Environments: Suitable for dry/damp environments with wall/ceiling mounting options. Seamlessly adapts to hospitals, schools, offices, restaurants, retail—virtually maintenance-free as a proven UVC Upper Air Disinfection solution.

Product Overview

The MASSPHOTON UVC Upper Air Disinfection System is an intelligent, sensor-based Upper-Room GUV/UVGI air disinfection solution designed for continuous operation in occupied spaces. Powered by advanced UVC LED technology, the system creates a controlled germicidal zone above occupant head height, where airborne pathogens and aerosols are continuously exposed to UVC radiation and inactivated.

By combining high-efficiency UVC LEDs with natural convection or mechanical ventilation, the system provides continuous, contact-free air disinfection without disrupting normal activities. Its modular and intelligent design makes it suitable for hospitals, schools, offices, restaurants, hotels, retail environments, and other high-traffic facilities.

The system can achieve up to 99.99% airborne pathogen reduction, depending on the target microorganism, environmental conditions, airflow, and installation configuration.


Key Features

Advanced UVC LED Technology

MASSPHOTON uses high-efficiency, mercury-free UVC LED technology as an alternative to conventional UV lamps. The system provides instant on/off operation, long service life, low maintenance, and environmentally friendly performance without mercury.

Its efficient design supports continuous operation with minimal maintenance, requiring only periodic cleaning and routine inspection.

Continuous Upper-Room UVGI Disinfection

The system establishes a persistent upper-room UVGI zone that continuously treats airborne microorganisms above occupied areas. Air naturally circulates through the treatment zone, allowing repeated exposure to UVC radiation and continuous reduction of airborne pathogens.

This approach is particularly effective for high-traffic environments where maintaining ongoing air hygiene is essential.

Smart Presence-Sensing Control

Integrated PIR presence sensors detect room occupancy and automatically adjust system operation according to the environment.

The intelligent control system can switch between active disinfection and energy-saving modes according to occupancy conditions, helping optimize energy consumption while maintaining effective air treatment.

Safe, Contact-Free Operation

The UVC irradiation zone is positioned above normal occupant height, allowing the system to operate while people remain in the room when properly installed and configured.

The process is chemical-free and produces no odors or chemical residues, supporting continuous air treatment without interrupting normal activities.

Flexible Installation & Wide Coverage

The modular design supports wall-mounted and ceiling-mounted configurations, allowing the system to integrate into a variety of indoor environments.

Its slim form factor can be incorporated into existing spaces and, where appropriate, combined with HVAC or mechanical ventilation systems to enhance air circulation and establish a comprehensive UVGI air disinfection strategy.

Scientific Validation

MASSPHOTON combines in-house research and third-party testing to evaluate UVC output, disinfection performance, and system safety. Performance data can be used to support application-specific engineering and installation requirements.


Typical Applications

The MASSPHOTON UVC Upper Air Disinfection System is designed for environments where continuous airborne pathogen control and improved indoor air hygiene are important.

Retail

Discreet upper-room UVC treatment provides continuous air disinfection in stores while maintaining a comfortable shopping environment.

Hotels

Suitable for hotel lobbies, guest areas, meeting spaces, and other shared environments requiring continuous air hygiene.

Restaurants

Provides upper-room air disinfection in dining areas, kitchens, and food-service environments to help reduce airborne contamination risks.

Fitness Centers

Designed for high-occupancy exercise environments where continuous air circulation and pathogen control are especially important.

Schools

Suitable for classrooms, corridors, libraries, and other educational spaces, supporting continuous air treatment without interrupting learning activities.

Assisted Living Facilities

Provides continuous upper-room air treatment in lounges, dining areas, activity rooms, and other shared spaces.

Commercial Offices

Ideal for open-plan offices, meeting rooms, reception areas, and other shared workspaces.

Healthcare & Laboratories

Suitable for selected healthcare, laboratory, isolation, and treatment environments where enhanced airborne infection-control measures are required.

Transportation & Waiting Areas

Designed for airports, metro stations, terminals, waiting lounges, and other high-traffic public areas requiring continuous air disinfection.


Technical Information

SpecificationDetails
ModelMP-UVC-15WR
UVC Peak Wavelength275 ± 5 nm
Radiant Flux (UVC Output)≥ 4.2 W @ 25°C ambient
Irradiance @ 1 mApprox. 41 μW/cm²
Rated Input VoltageDC 36V
Rated Power15W
Operating Current1.7A
Lamp Body MaterialAluminum alloy heat-dissipation base + quartz glass
Protection ClassIP20 — dust protected, not waterproof
InstallationStandard mounting clips
Heat DissipationActive fan cooling with side air outlets
Ambient Temperature-20°C to +40°C
Storage Temperature-30°C to +60°C
Relative Humidity< 85% RH, non-condensing

Installation Note: The side air outlets must remain unobstructed to ensure proper cooling and reliable operation.